BESS Initial Charge-Discharge and AGC Response Test
1号集装箱全部预检通过。BMS在线、896个电芯在30% SOC下平衡在15 mV 以内。PCS已连接待机、HVAC保持箱内23°C。现在做首次充放电容量测试。这 将建立基线容量、以后所有衰减都以此为基准对标质保。开始充电。
0.3C(750 kW)恒功率充电。电芯电压均匀上升——50% SOC时全部896个 电芯彼此偏差在18 mV内、80% SOC时22 mV。95% SOC时BMS开始给高电芯放电 ——均衡电流每芯80 mA。接近3.65V时从CC转为CV模式。总充电时间4小时12 分。充电能量:2,531.5 kWh(DC侧)。静置30分钟让电芯稳定。
现在0.5C(1.25 MW)恒功率放电到5% SOC。放电完成——持续2小时1分。放 电能量:2,198.3 kWh(DC侧)。DC充放电效率:2,198.3/2,531.5 = 86.8%。 含PCS损耗(~97.5%)后AC端效率约84.6%。测试容量在铭牌2.5 MWh的101.3% ——新电芯略超发正常。基线已建立。6个月和12个月复测跟踪衰减。
敖工,现在测试AGC响应。电网发模拟AGC信号:从0 MW阶跃到+25 MW放 电、然后反转到-25 MW充电。这测试BESS的快爬坡能力。
EMS收到AGC信号、同步下发到全部10台PCS。以25 MW每秒爬坡放电…… 1.1秒达到+25 MW。直流电流各簇均衡——每簇贡献约250 kW。现在反转到 -25 MW充电……从初始指令总计2.3秒完成反转。BESS能在3秒以内甩过全部50 MW范围。这就是电网级储能的价值所在——没有任何常规电源能匹敌的响应速 度。